Not necessarily, The 5/8-inch, “fire-code” drywall (called Type X) increases a wall’s fire rating to a minimum of 1 hour, from the 30-minute rating for standard ½-inch drywall. The IRC code requires 1/2″ rock on the garage side of the garage walls and any supporting structure (steel posts, stud walls, etc).

What color is best for garage walls?

Keep it simple! I recommend white, but if you want something a bit different then paint your garage a light shade of gray, beige or blue because lighter shades make a room seem bigger than it actually is. The color of your walls also needs to compliment your cabinets and floor so the entire garage looks cohesive.

Do I need mold resistant drywall in garage?

Mold/mildew will grow if the moisture is trapped. Re: mold resistant drywall? As far as I know the 5/8″ is only required as a firewall in an attached garage between the garage and house. 1/2″ is ok for the other walls or for a detached garage, although some people here like thicker sheeetrock for puncture protection.

Should I insulate garage walls?

You do not need to insulate the entire garage, you could actually do fine insulating just the internal wall of the garage. This helps prevent the escape of heat from out of the walls of your home during the winter time and vice versa during the warmer months.

How much does it cost to drywall a garage?

At the time of publication, the cost of a 5/8 inch thick, 4-by-8-foot drywall sheet averages $12 per sheet. A 20-by-24-feet two-car garage has 800 square feet requiring coverage when you include the ceiling. This equates to 25 sheets at a cost of $300.

See also  What do different birds symbolize?

What can I use instead of drywall in garage?

Solid Cement Board

Instead of drywall, consider covering garage walls with cement board panels. These panels make it easy to add tile, or even stone veneer. Using stone veneer over cement board, you can create an exposed brick or natural stone wall in the garage.

Where is Firecode drywall required?

In residences, fire-rated drywall is typically required by building codes to be installed in a few of these places: Near furnace and utility rooms. Places where a wood stove is used. Garages and especially the garage walls that separate that area from the main house.

How thick does drywall have to be in a garage?

Also, ?” is the standard thickness for fire-resistant or fire-code drywall, commonly found in garages. ¼” drywall is relatively uncommon, and can be used for repairs or for curved areas, where you can double up two sheets to make a standard ½” sheet.

What can I use for garage walls?

Fiberboard is a utility material made from wood chips that comes in various densities, and the type most suitable for garage walls is hardboard, which typically comes in sheets that are 1/4 inch thick. It’s lightweight, easy to nail to the studs, and has a smooth surface that you can paint or leave as is.

Is paneling cheaper than drywall?

Cheap 3/16 inch fake wood or patterned panels can cost around $10 per panel. A decent real wood veneer can soar to $40 each. It is common practice to put paneling over drywall. If anything, if paneling is not installed over drywall, the seams can be a source of air infiltration, negating any insulation value.

What type of door goes between garage and house?

Doors between a house and a garage can be one of three types, take your pick: Solid wood, at least 1-3/8″ thick. Solid or honeycomb-core steel, at least 1-3/8″ thick. 20-minute fire-rated.

What is a residential firewall?

Most people don’t understand what is a firewall in a house. A firewall is a fire-resistant barrier used to prevent the spread of fire for a prescribed period of time. In this case, the firewall between the storage area and living space was able to contain the fire and prevent it from consuming the whole house.

Consequently, what is code for drywall in a garage?

The 5/8-inch, “fire-code” drywall (called Type X) increases a wall’s fire rating to a minimum of 1 hour, from the 30-minute rating for standard ½-inch drywall. walls separating an attached garage from the house, and around the boiler in multiple-family dwellings.

See also  How do you use a magic lighting remote controller?

Beside this, do garages need drywall?

You do not need 5/8″ drywall for the garage walls. In the US, you need it between the garage and living space, but not on the exterior walls. I also recommend thinking about adding some outlets before you close the walls up – so much easier than doing it later.

Can a bedroom be next to a garage?

Nope, bedrooms should NOT open into a garage. This could be a small closet-sized space, with a fire-rated, self-closing door on the garage side, for firewall compliance. In this way, you could have your attached garage, your added bedroom, and no direct access between the two.

What size drywall do I need?

Drywall comes in sheets. While the most common size is 4 x 8 feet, you can purchase much larger lengths. Use a sheet size that minimizes the number of seams that will appear in the finished product. Drywall comes in various thicknesses, 3/8 inch and 1/2 inch being the most common.

What kind of drywall do you use in a garage?

Standard drywall panels contain compressed particles of gypsum covered with thick paper. That’s fine in your home, but unless you’re finishing your garage as a living space, complete with insulation and a heat and air system, moisture-resistant drywall is preferable.

What is code for drywall on ceilings?

When applying a water-based texture material, the minimum gypsum board thickness shall be increased from 3/8 inch to 1/2 inch for 16-inch on center framing, and from 1/2 inch to 5/8 inch for 24-inch on center framing or 1/2-inch sag-resistant gypsum ceiling board shall be used. e.

Similarly, is drywall required by code?

Thicker drywall may be required by code for any wall or ceiling covered with a texture or skim coat where studs or joists are spaced 24 inches on-center rather than 16 inches. This thicker drywall is often called fire-resistant drywall.

What is the code for drywall screws?

Both the International Residential Code (IRC) and USG, the manufacturer of Sheetrock, say that maximum field screw spacing for wall drywall is 16 inches. Some builders like to space fasteners tighter than that, so they go down to 12 inches.

What is the fire rating of 5/8 drywall?

Type X fire rated gypsum drywall that is 5/8 -inch (15.9mm) thick and installed on each side of nominal 2-inch x 4-inch (38x89mm) wood studs spaced 16-inch (400mm) o.c. or 3-5/8 inch (610 mm) steel studs spaced 24″ o.c. has a minimum fire rating for the assembly of 1 hour, which is a typical requirement for many